The overlap of sealing tape and
sealing tape or sealing tape and
inner or outer corner must be at
least 5 cm.
The sealing tapes in the wall/
floor connection are applied by
spreading the CLASSEN Multi-
connect adhesive over the entire
surface to above the edge of the
membrane using a B3 toothed
spreader in accordance with the
manufacturer’s instructions.
Completed area must be inspe-
cted for defects or damage
(e.g. perforations).
Leaky or unclean areas must be
cient tightness is ensured.
The membranes are then bonded
over the entire surface. Firm
pressing guarantees full-surface
bonding. Air bubble entrapment
must be avoided by pressing on
and carefully spreading out with
a smoothening spatula.
ATTENTION: Waterproofing membranes, sealing tapes as
well as system components must be carefully processed
with new sharp tools. These sealing components must not
be damaged in the process, as this would lead to leaks.
The waterproofing is complete when it is fully bonded to all
surfaces.
TIP: Residual and
waste material can
be disposed of prop-
erly in the residual
waste.
5 cm
5 cm
WATERPROOFING ACCORDING TO DIN 18534